Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net
Magnetic resonance angiography (MRA) is an important tool for aortic assessment in several cardiovascular diseases. Assessment of MRA images relies on manual segmentation, a time-intensive process that is subject to operator variability. We aimed to optimize and validate two deep-learning models for...
| Autores: | , , , , , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2025 |
| País: | España |
| Institución: | Universitat Autònoma de Barcelona |
| Repositorio: | Dipòsit Digital de Documents de la UAB |
| Idioma: | inglés |
| OAI Identifier: | oai:ddd.uab.cat:326295 |
| Acceso en línea: | https://ddd.uab.cat/record/326295 https://dx.doi.org/urn:doi:10.1016/j.jocmr.2025.101923 |
| Access Level: | acceso abierto |
| Palabra clave: | Aorta Aortic disease Magnetic resonance angiography Segmentation Deep-learning nnUNet |
| id |
ES_8d7eea2d6746fb992cb00432d1dca51b |
|---|---|
| oai_identifier_str |
oai:ddd.uab.cat:326295 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-NetCesario, MatteoLittlewood, Simon J.Nadel, JamesFletcher, Thomas J.Fotaki, AnastasiaCastillo-Passi, CarlosHajhosseiny, RezaPouliopoulos, JimJabbour, AndrewOlivero, RupertoRodríguez Palomares, José Fernando|||0000-0002-8822-5532Kooi, M. ElinePrieto, ClaudiaBotnar, René M.AortaAortic diseaseMagnetic resonance angiographySegmentationDeep-learningnnUNetMagnetic resonance angiography (MRA) is an important tool for aortic assessment in several cardiovascular diseases. Assessment of MRA images relies on manual segmentation, a time-intensive process that is subject to operator variability. We aimed to optimize and validate two deep-learning models for automatic segmentation of the aortic lumen and vessel wall in high-resolution electrocardiogram-triggered free-breathing respiratory motion-corrected three-dimensional (3D) bright- and black-blood MRA images. Manual segmentation, serving as the ground truth, was performed on 25 bright-blood and 15 black-blood 3D MRA image sets acquired with the iT2PrepIR-BOOST sequence (1.5T) in thoracic aortopathy patients. The training was performed with no new U-Net (nnUNet) for bright-blood (lumen) and black-blood image sets (lumen and vessel wall). Training consisted of a 70:20:10% (17/25:5/25:3/25 datasets) training:validation:testing split. Inference was run on datasets (single vendor) from different centers (UK, Spain, and Australia), sequences (iT2PrepIR-BOOST, T2 prepared coronary magnetic resonance angiography [CMRA], and time-resolved angiography with interleaved stochastic trajectories [TWIST] MRA), acquired resolutions (from 0.9-3 mm 3), and field strengths (0.55T, 1.5T, and 3T). Predictive measurements comprised Dice similarity coefficient (DSC) and Intersection over Union (IoU). Postprocessing (3D slicer) included centreline extraction, diameter measurement, and curved planar reformatting (CPR). The optimal configuration was the 3D U-Net. Bright-blood segmentation at 1.5T on iT2PrepIR-BOOST datasets (1.3 and 1.8 mm 3) and 3D CMRA datasets (0.9 mm 3) resulted in DSC ≥ 0.96 and IoU ≥ 0.92. For bright-blood segmentation on 3D CMRA at 0.55T, the nnUNet achieved DSC and IoU scores of 0.93 and 0.88 at 1.5 mm³, and 0.68 and 0.52 at 3.0 mm³, respectively. DSC and IoU scores of 0.89 and 0.82 were obtained for CMRA image sets (1 mm 3) at 1.5T (Barcelona dataset). DSC and IoU scores of the BRnnUNet model were 0.90 and 0.82, respectively, for the contrast-enhanced dataset (TWIST MRA). Lumen segmentation on black-blood 1.5T iT2PrepIR-BOOST image sets achieved DSC ≥ 0.95 and IoU ≥ 0.90, and vessel wall segmentation resulted in DSC ≥ 0.80 and IoU ≥ 0.67. Automated centreline tracking, diameter measurement, and CPR were successfully implemented in all subjects. Automated aortic lumen and wall segmentation on 3D bright- and black-blood image sets demonstrated excellent agreement with ground truth. This technique demonstrates a fast and comprehensive assessment of aortic morphology with great potential for future clinical application in various cardiovascular diseases. 22025-01-0120252025-01-01Articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://ddd.uab.cat/record/326295https://dx.doi.org/urn:doi:10.1016/j.jocmr.2025.101923reponame:Dipòsit Digital de Documents de la UABinstname:Universitat Autònoma de BarcelonaInglésengopen accesshttp://purl.org/coar/access_right/c_abf2Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original.https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:ddd.uab.cat:3262952026-06-06T12:50:31Z |
| dc.title.none.fl_str_mv |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net |
| title |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net |
| spellingShingle |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net Cesario, Matteo Aorta Aortic disease Magnetic resonance angiography Segmentation Deep-learning nnUNet |
| title_short |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net |
| title_full |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net |
| title_fullStr |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net |
| title_full_unstemmed |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net |
| title_sort |
Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net |
| dc.creator.none.fl_str_mv |
Cesario, Matteo Littlewood, Simon J. Nadel, James Fletcher, Thomas J. Fotaki, Anastasia Castillo-Passi, Carlos Hajhosseiny, Reza Pouliopoulos, Jim Jabbour, Andrew Olivero, Ruperto Rodríguez Palomares, José Fernando|||0000-0002-8822-5532 Kooi, M. Eline Prieto, Claudia Botnar, René M. |
| author |
Cesario, Matteo |
| author_facet |
Cesario, Matteo Littlewood, Simon J. Nadel, James Fletcher, Thomas J. Fotaki, Anastasia Castillo-Passi, Carlos Hajhosseiny, Reza Pouliopoulos, Jim Jabbour, Andrew Olivero, Ruperto Rodríguez Palomares, José Fernando|||0000-0002-8822-5532 Kooi, M. Eline Prieto, Claudia Botnar, René M. |
| author_role |
author |
| author2 |
Littlewood, Simon J. Nadel, James Fletcher, Thomas J. Fotaki, Anastasia Castillo-Passi, Carlos Hajhosseiny, Reza Pouliopoulos, Jim Jabbour, Andrew Olivero, Ruperto Rodríguez Palomares, José Fernando|||0000-0002-8822-5532 Kooi, M. Eline Prieto, Claudia Botnar, René M. |
| author2_role |
author author author author author author author author author author author author author |
| dc.subject.none.fl_str_mv |
Aorta Aortic disease Magnetic resonance angiography Segmentation Deep-learning nnUNet |
| topic |
Aorta Aortic disease Magnetic resonance angiography Segmentation Deep-learning nnUNet |
| description |
Magnetic resonance angiography (MRA) is an important tool for aortic assessment in several cardiovascular diseases. Assessment of MRA images relies on manual segmentation, a time-intensive process that is subject to operator variability. We aimed to optimize and validate two deep-learning models for automatic segmentation of the aortic lumen and vessel wall in high-resolution electrocardiogram-triggered free-breathing respiratory motion-corrected three-dimensional (3D) bright- and black-blood MRA images. Manual segmentation, serving as the ground truth, was performed on 25 bright-blood and 15 black-blood 3D MRA image sets acquired with the iT2PrepIR-BOOST sequence (1.5T) in thoracic aortopathy patients. The training was performed with no new U-Net (nnUNet) for bright-blood (lumen) and black-blood image sets (lumen and vessel wall). Training consisted of a 70:20:10% (17/25:5/25:3/25 datasets) training:validation:testing split. Inference was run on datasets (single vendor) from different centers (UK, Spain, and Australia), sequences (iT2PrepIR-BOOST, T2 prepared coronary magnetic resonance angiography [CMRA], and time-resolved angiography with interleaved stochastic trajectories [TWIST] MRA), acquired resolutions (from 0.9-3 mm 3), and field strengths (0.55T, 1.5T, and 3T). Predictive measurements comprised Dice similarity coefficient (DSC) and Intersection over Union (IoU). Postprocessing (3D slicer) included centreline extraction, diameter measurement, and curved planar reformatting (CPR). The optimal configuration was the 3D U-Net. Bright-blood segmentation at 1.5T on iT2PrepIR-BOOST datasets (1.3 and 1.8 mm 3) and 3D CMRA datasets (0.9 mm 3) resulted in DSC ≥ 0.96 and IoU ≥ 0.92. For bright-blood segmentation on 3D CMRA at 0.55T, the nnUNet achieved DSC and IoU scores of 0.93 and 0.88 at 1.5 mm³, and 0.68 and 0.52 at 3.0 mm³, respectively. DSC and IoU scores of 0.89 and 0.82 were obtained for CMRA image sets (1 mm 3) at 1.5T (Barcelona dataset). DSC and IoU scores of the BRnnUNet model were 0.90 and 0.82, respectively, for the contrast-enhanced dataset (TWIST MRA). Lumen segmentation on black-blood 1.5T iT2PrepIR-BOOST image sets achieved DSC ≥ 0.95 and IoU ≥ 0.90, and vessel wall segmentation resulted in DSC ≥ 0.80 and IoU ≥ 0.67. Automated centreline tracking, diameter measurement, and CPR were successfully implemented in all subjects. Automated aortic lumen and wall segmentation on 3D bright- and black-blood image sets demonstrated excellent agreement with ground truth. This technique demonstrates a fast and comprehensive assessment of aortic morphology with great potential for future clinical application in various cardiovascular diseases. |
| publishDate |
2025 |
| dc.date.none.fl_str_mv |
2 2025-01-01 2025 2025-01-01 |
| dc.type.none.fl_str_mv |
Article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://ddd.uab.cat/record/326295 https://dx.doi.org/urn:doi:10.1016/j.jocmr.2025.101923 |
| url |
https://ddd.uab.cat/record/326295 https://dx.doi.org/urn:doi:10.1016/j.jocmr.2025.101923 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 https://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 https://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:Dipòsit Digital de Documents de la UAB instname:Universitat Autònoma de Barcelona |
| instname_str |
Universitat Autònoma de Barcelona |
| reponame_str |
Dipòsit Digital de Documents de la UAB |
| collection |
Dipòsit Digital de Documents de la UAB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869413050686111744 |
| score |
15.812455 |