Evaluation level of Failure Mechanism in a 20-year-old construction

The impact and visible consequences of damage to the structure of a building after natural or anthropogenic phenomena caused by reaction forces in response to the loads received, are typified according to the area of ​​occurrence, their presence gives indications of vulnerability. Safe structural sy...

Full description

Bibliographic Details
Authors: Hernández-Cid , Monserrat, Cerón-Carballo, Jesús Emmanuel, Beltrán-Martínez , Yoan Saidt, Pérez-Isidro , Eber, Guerrero-Rodríguez , Mauricio, Cerón-Castelán , Carlos Abraham
Format: article
Status:Published version
Publication Date:2024
Country:México
Institution:UNIVERSIDAD AUTÓNOMA DEL ESTADO DE HIDALGO
Repository:PÄDI Boletín Científico de Ciencias Básicas e Ingeniería del ICBI
Language:Spanish
OAI Identifier:oai:repository.uaeh.edu.mx:article/11067
Online Access:https://repository.uaeh.edu.mx/revistas/index.php/icbi/article/view/11067
Access Level:Open access
Keyword:Structural damage
Modal analysis
Risk
Vibrations
Instability
Daño estructural
Análisis modal
Riesgo
Vibraciones
Inestabilidad
Description
Summary:The impact and visible consequences of damage to the structure of a building after natural or anthropogenic phenomena caused by reaction forces in response to the loads received, are typified according to the area of ​​occurrence, their presence gives indications of vulnerability. Safe structural systems are those that maintain a suitable type of structure built with high quality materials and construction procedures immersed in current regulations, resulting in a favorable performance against any threat, in the present study the evaluation of a structure with age of 20 years, the method of experimental modal analysis implemented on site is used, it was observed that the conditions of the structure before the response of vibrations maintains a structural level of zero risk, result after carrying out a structural survey to find the magnitudes of the service criteria.