Impact of scanning distance on the accuracy of a photogrammetry system

Purpose: To measure the impact of the scanning distance on the accuracy of complete-arch implant scans acquired by using a photogrammetry (PG) system. Material and methods: An edentulous cast with 6 implant abutment analogs was obtained. A brand new implant scan body was positioned on each implant a...

ver descrição completa

Detalhes bibliográficos
Autores: Revilla León, Marta, Gómez Polo, Miguel Ángel, Drone, Michael, Barmak, Abdul B., Guinot Barona, Clara, Att, Wael, Kois, John C., Alonso Pérez-Barquero, Jorge
Formato: artículo
Fecha de publicación:2024
País:España
Recursos:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/109338
Acesso em linha:https://hdl.handle.net/20.500.14352/109338
Access Level:acceso abierto
Palavra-chave:616.314-089.843
616.314-089.28
616-073.75
Accuracy
Digital impression
Implant scan
Intraoral scanner
Photogrammetry
Odontología (Odontología)
Ciencias Biomédicas
Implantes dentales
Prótesis dental
Diagnóstico por imagen y medicina nuclear
32 Ciencias Médicas
3213.13 Ortodoncia-Estomatología
3213 Cirugía
3314.02 Prótesis
2209.90 Tratamiento Digital. Imágenes
Descrição
Resumo:Purpose: To measure the impact of the scanning distance on the accuracy of complete-arch implant scans acquired by using a photogrammetry (PG) system. Material and methods: An edentulous cast with 6 implant abutment analogs was obtained. A brand new implant scan body was positioned on each implant abutment and digitized using an extraoral scanner (T710; Medit) and the reference file was obtained. Three groups were created based on the scanning distance used to acquire complete-arch implant scans by using a PG (PIC System; PIC Dental): 20 (20 group), 30 (30 group), and 35 cm (35 group). An optical marker (PIC Transfer, HC MUA Metal; PIC Dental) was placed on each implant abutment and a total of thirty scans per group were acquired. Euclidean linear and angular measurements were obtained on the reference file was obtained and used to compare the discrepancies with the same measurements obtained on each experimental scan. One-way ANOVA and Tukey tests were used to analyze trueness. The Levene test was used to analyze the precision values (α = 0.05). Results: Significant linear (P < .001) and angular trueness (P < .001) discrepancies were found among the groups. For linear trueness, Tukey test showed that the 20 and 30 groups (P < .001) and 30 and 35 groups were different (P < .001). For angular trueness, the Tukey test revealed that 20 and 30 groups (P = .003), 20 and 35 (P < .001), and 30 and 35 groups were different (P < .001) The Levene test showed no significant linear precision (P = .197) and angular discrepancies (P = .229) among the groups. Conclusions: The scanning distance influenced the trueness of complete-arch implant scans obtained with the PG method tested. The maximum linear trueness mean discrepancy among the groups tested was 10 µm and the maximum angular trueness mean discrepancy among the groups tested was 0.02 .