Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples
A needle trap (NT) device filled with Carbopack X as a sorbent material is evaluated for the static headspace analysis of benzene, toluene, ethylbenzene, and xylene (BTEX) compounds in aqueous samples. Injection parameters used with the NT device (e.g. volume of carrier gas and time to open the spli...
| Autores: | , , , , , |
|---|---|
| Tipo de documento: | artigo |
| Estado: | Versión aceptada para publicación |
| Data de publicação: | 2010 |
| País: | España |
| Recursos: | Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| Repositório: | Recercat. Dipósit de la Recerca de Catalunya |
| OAI Identifier: | oai:recercat.cat:10256/26036 |
| Acesso em linha: | http://hdl.handle.net/10256/26036 |
| Access Level: | Acceso aberto |
| Palavra-chave: | Adsorció Separació (Tecnologia) Adsorption Separation (Technology) Compostos orgànics volàtils Volatile organic compounds |
| id |
ES_e48aa86f73ce2b43e259da4fe42f3b0b |
|---|---|
| oai_identifier_str |
oai:recercat.cat:10256/26036 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samplesDe Crom, JornClaeys, SaraGodayol Boix, AnnaAlonso Roura, MònicaAnticó i Daró, Ma. EnriquetaSánchez Navarro, Juan ManuelAdsorcióSeparació (Tecnologia)AdsorptionSeparation (Technology)Compostos orgànics volàtilsVolatile organic compoundsA needle trap (NT) device filled with Carbopack X as a sorbent material is evaluated for the static headspace analysis of benzene, toluene, ethylbenzene, and xylene (BTEX) compounds in aqueous samples. Injection parameters used with the NT device (e.g. volume of carrier gas and time to open the split valve) are evaluated to determine the mechanism involved during the desorption and transferring of the target compounds into the GC column. Furthermore, different parameters affecting the adsorption capacity of the sorbent are studied (e.g. sampling time and temperature, headspace/sample volume ratio, salting-out, and stirring). The evaluation of the method with aqueous samples shows that repeatability and recoveries with the NT device are equivalent to those obtained using solid-phase microextraction with a carboxen/PDMS (CAR/PDMS) coating. LODs obtained with flame ionization detection are in the range of 10-25 μg/L, and in the range of hundredths of μg/L with MS detection. The method developed is satisfactorily applied to the analysis of aqueous samples obtained from wastewater treatment plantsResearch funding: MICINN. Grant Number: CTM2008-06847-C02-02/TECNO and Spanish Ministry of Education (FPU). Grant Number: AP2008-01628Wiley-VCH VerlagMinisterio de Educación y Ciencia (Espanya)2010info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionpeer reviewed8 p.application/pdfhttp://hdl.handle.net/10256/26036http://hdl.handle.net/10256/26036© Journal of Separation Science, 2010, vol. 33, núm. 17-18, p. 2833-2840Articles publicats (D-Q)De Crom, Jorn Claeys, Sara Godayol Boix, Anna Alonso Roura, Mònica Anticó i Daró, Ma. Enriqueta Sánchez Navarro, Juan Manuel 2010 Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples Journal of Separation Science 33 17-18 2833 2840reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)Inglésinfo:eu-repo/semantics/altIdentifier/doi/10.1002/jssc.201000213info:eu-repo/semantics/altIdentifier/issn/1615-9306info:eu-repo/semantics/altIdentifier/eissn/1615-9314info:eu-repo/grantAgreement/MICINN//CTM2008-06847-C02-02EVALUACION DE LA EFICACIA DE LAS PLANTAS DE TRATAMIENTO DE AGUAS RESIDUALES EN LA ELIMINACION DE COMPUESTOS ORGANICOS EMERGENTES DE LAS AGUAS PARA SU REUTILIZACIONTots els drets reservatsinfo:eu-repo/semantics/openAccessoai:recercat.cat:10256/260362026-05-29T05:05:01Z |
| dc.title.none.fl_str_mv |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples |
| title |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples |
| spellingShingle |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples De Crom, Jorn Adsorció Separació (Tecnologia) Adsorption Separation (Technology) Compostos orgànics volàtils Volatile organic compounds |
| title_short |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples |
| title_full |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples |
| title_fullStr |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples |
| title_full_unstemmed |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples |
| title_sort |
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples |
| dc.creator.none.fl_str_mv |
De Crom, Jorn Claeys, Sara Godayol Boix, Anna Alonso Roura, Mònica Anticó i Daró, Ma. Enriqueta Sánchez Navarro, Juan Manuel |
| author |
De Crom, Jorn |
| author_facet |
De Crom, Jorn Claeys, Sara Godayol Boix, Anna Alonso Roura, Mònica Anticó i Daró, Ma. Enriqueta Sánchez Navarro, Juan Manuel |
| author_role |
author |
| author2 |
Claeys, Sara Godayol Boix, Anna Alonso Roura, Mònica Anticó i Daró, Ma. Enriqueta Sánchez Navarro, Juan Manuel |
| author2_role |
author author author author author |
| dc.contributor.none.fl_str_mv |
Ministerio de Educación y Ciencia (Espanya) |
| dc.subject.none.fl_str_mv |
Adsorció Separació (Tecnologia) Adsorption Separation (Technology) Compostos orgànics volàtils Volatile organic compounds |
| topic |
Adsorció Separació (Tecnologia) Adsorption Separation (Technology) Compostos orgànics volàtils Volatile organic compounds |
| description |
A needle trap (NT) device filled with Carbopack X as a sorbent material is evaluated for the static headspace analysis of benzene, toluene, ethylbenzene, and xylene (BTEX) compounds in aqueous samples. Injection parameters used with the NT device (e.g. volume of carrier gas and time to open the split valve) are evaluated to determine the mechanism involved during the desorption and transferring of the target compounds into the GC column. Furthermore, different parameters affecting the adsorption capacity of the sorbent are studied (e.g. sampling time and temperature, headspace/sample volume ratio, salting-out, and stirring). The evaluation of the method with aqueous samples shows that repeatability and recoveries with the NT device are equivalent to those obtained using solid-phase microextraction with a carboxen/PDMS (CAR/PDMS) coating. LODs obtained with flame ionization detection are in the range of 10-25 μg/L, and in the range of hundredths of μg/L with MS detection. The method developed is satisfactorily applied to the analysis of aqueous samples obtained from wastewater treatment plants |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion peer reviewed |
| format |
article |
| status_str |
acceptedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10256/26036 http://hdl.handle.net/10256/26036 |
| url |
http://hdl.handle.net/10256/26036 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
info:eu-repo/semantics/altIdentifier/doi/10.1002/jssc.201000213 info:eu-repo/semantics/altIdentifier/issn/1615-9306 info:eu-repo/semantics/altIdentifier/eissn/1615-9314 info:eu-repo/grantAgreement/MICINN//CTM2008-06847-C02-02 EVALUACION DE LA EFICACIA DE LAS PLANTAS DE TRATAMIENTO DE AGUAS RESIDUALES EN LA ELIMINACION DE COMPUESTOS ORGANICOS EMERGENTES DE LAS AGUAS PARA SU REUTILIZACION |
| dc.rights.none.fl_str_mv |
Tots els drets reservats info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Tots els drets reservats |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
8 p. application/pdf |
| dc.publisher.none.fl_str_mv |
Wiley-VCH Verlag |
| publisher.none.fl_str_mv |
Wiley-VCH Verlag |
| dc.source.none.fl_str_mv |
© Journal of Separation Science, 2010, vol. 33, núm. 17-18, p. 2833-2840 Articles publicats (D-Q) De Crom, Jorn Claeys, Sara Godayol Boix, Anna Alonso Roura, Mònica Anticó i Daró, Ma. Enriqueta Sánchez Navarro, Juan Manuel 2010 Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples Journal of Separation Science 33 17-18 2833 2840 reponame:Recercat. Dipósit de la Recerca de Catalunya instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| instname_str |
Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| reponame_str |
Recercat. Dipósit de la Recerca de Catalunya |
| collection |
Recercat. Dipósit de la Recerca de Catalunya |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869422599932477440 |
| score |