Automatic segmentation of exudates in colour retinal fundus images

This work aims at the development of an algorithm that allows the automatic detection of exudates in retinal fundus images. The detection of exudates allows diabetic retinopathy (DR) to be diagnosed, consequently it is an important task for the control and the treatment of people suffering DR. In ad...

Full description

Bibliographic Details
Author: Maynau Hernandez, Cristina
Format: master thesis
Publication Date:2019
Country:España
Institution:Universitat Politècnica de Catalunya (UPC)
Repository:UPCommons. Portal del coneixement obert de la UPC
Language:Portuguese
OAI Identifier:oai:upcommons.upc.edu:2117/174823
Online Access:https://hdl.handle.net/2117/174823
Access Level:Open access
Keyword:Reina -- Diseases
Diagnostic imaging
Retina -- Malalties
Imatgeria per al diagnòstic
Àrees temàtiques de la UPC::Ciències de la salut
Description
Summary:This work aims at the development of an algorithm that allows the automatic detection of exudates in retinal fundus images. The detection of exudates allows diabetic retinopathy (DR) to be diagnosed, consequently it is an important task for the control and the treatment of people suffering DR. In addition, an increase of 35\% of people suffering from diabetes is predicted and, therefore, of people who will suffer from DR in the coming years. As a result, an important burden for ophthalmologists will be expected. For all this, it's highly needed the development of an automatic system for the detection of exudates. Two different algorithms are proposed. Background subtraction to deal with uneven illumination and mathematical morphology operators are used for exudate location. Finally, dynamic thresholding is applied for exudate segmentation. In the first algorithm dynamic thresholding is combined with the Kirsch edge detector. In the second one, a template and morphological operators are used to differentiate bright elements from exudates is used. The methods have been validated in three public datasets named e-ophta-EX, HEI-MED and DiaretDB1. The first two datasets have been used to validated the algorithms both at lesion level and image-level. However, DiaretDB1 was only used to validate the algorithms at image-level due to its ground truth does not mark exact boundaries of exudates. The results for the image-level validation are better for the second algorithm obtaining an AUC of 0.84, 0.75 and 0.84 for e-ophta-EX, HEI-MED and DiaretDB1, respectively. The results obtained with the evaluation at lesion-level are the same for the two methods and are quantified in terms of sensitivity and PPV. We have achieved values of sensitivity and PPV of 0.54 and 0.52, respectively, in e-ophta-EX and, 0.52 and 0.52, respectively, in HEI-MED for method 1. For method 2, we have obtained values for sensitivity and PPV of 0.5 and 0.57, respectively, for e-ophta-EX and 0.42 and 0.76, respectively, for HEI-MED.