Influence of the structural components of artificial turf systems on impact attenuation in amateur football players

The objective of this research was to evaluate the influence of the structural components of different third-generation artificial turf soccer field systems on the biomechanical response of impact attenuation in amateur soccer players. A total of 12 amateur soccer players (24.3 ± 3.7 years, 73.5 ± 5...

Descripción completa

Detalles Bibliográficos
Autores: Sánchez Sánchez, Javier, Gallardo Guerrero, Ana María, García Gallart, Antonio, Sánchez Sáez, Juan Antonio, Felipe, José Luis, Encarnación Martínez, Alberto
Tipo de recurso: artículo
Fecha de publicación:2019
País:España
Institución:Universidad Católica San Antonio de Murcia (UCAM)
Repositorio:RIUCAM. Repositorio Institucional de la Universidad Católica San Antonio de Murcia
OAI Identifier:oai:repositorio.ucam.edu:10952/9021
Acceso en línea:http://hdl.handle.net/10952/9021
Access Level:acceso abierto
Palabra clave:Artificial turf
Structural components
Impact attenuation
Descripción
Sumario:The objective of this research was to evaluate the influence of the structural components of different third-generation artificial turf soccer field systems on the biomechanical response of impact attenuation in amateur soccer players. A total of 12 amateur soccer players (24.3 ± 3.7 years, 73.5 ± 5.5 kg, 178.3 ± 4.1 cm, and 13.7 ± 4.3 years of sport experience) were evaluated on three third-generation artificial turf systems (ATS) with different structural components. The ATSs were composed of an asphalt subbase and a fiber height of 45 mm with (ATS1) and without (ATS2) elastic layer or a compacted granular subbase, a fiber height of 60 mm without elastic layer (ATS3). Two triaxial accelerometers were firmly attached to the forehead and distal end of the right tibia of each individual. The results reveal a greater force reduction in ATS3 compared to ATS1 (+6.24 %, 95%CI: 1.67 to 10.92, ES: 1.07; p < 0.05) and ATS2 (+21.08 %, 95%CI: 16.51 to 25.66, ES: 2.98; p < 0.05) elastic layer. The tibia acceleration rate was lower in ATS3 than in ATS1 (-0.32, 95%CI: -0.60 to -0.03, ES: 4.23; p < 0.05) and ATS2 (-0.35, 95%CI: -0.64 to -0.06; ES: 4.69; p < 0.05) at 3.3 m/s. A very large correlation (r = 0.7 to 0.9; p < 0.05) was found between energy restitution and fiber height in both peak head and tibial acceleration and stride time. In conclusion, the structural components (fiber height, infill, subbase and elastic layer) determine the mechanical properties of artificial turf fields. Higher force reduction and lower energy restitution decreased the impact received by the player, which could protect against impact-associated injuries compared to harder artificial turf surfaces.