Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites
Cocaine, cannabis, heroin, and other opioids are among the prevalent drugs in Europe. The use of these drugs is demonstrated by the determination of either parent drugs or related metabolites in a variety of biological samples. Various analytical methodologies can be applied for this purpose, all of...
| Autores: | , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2017 |
| País: | España |
| Institución: | Universidad de Alcalá (UAH) |
| Repositorio: | e_Buah Biblioteca Digital Universidad de Alcalá |
| Idioma: | inglés |
| OAI Identifier: | oai:ebuah.uah.es:10017/48607 |
| Acceso en línea: | http://hdl.handle.net/10017/48607 https://dx.doi.org/10.1039/C7AY00813A |
| Access Level: | acceso abierto |
| Palabra clave: | GC-MS Cocaine Heroin Cannabis Opioids Química Chemistry |
| id |
ES_c2ecd441068a737f3a2c0235b409a562 |
|---|---|
| oai_identifier_str |
oai:ebuah.uah.es:10017/48607 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolitesSaiz Galindo, JorgeGarcía Ruiz, Carmen|||0000-0001-5925-3449Gómara Moreno, BelénGC-MSCocaineHeroinCannabisOpioidsQuímicaChemistryCocaine, cannabis, heroin, and other opioids are among the prevalent drugs in Europe. The use of these drugs is demonstrated by the determination of either parent drugs or related metabolites in a variety of biological samples. Various analytical methodologies can be applied for this purpose, all of which might show relevant differences in analytical performance. In this work we used different GC-MS configurations for the quantitation of cocaine, cocaethylene, benzoylecgonine, morphine, and Delta9-tetrahydrocannabinol with the aim of comparing the analytical performance of different GC-MS instruments, different injectors, ion sources, ionization modes, mass analyzers, operating modes, and acquisition modes, in order to find the optimal configuration in terms of sensitivity and precision. Other important factors, such as the derivatization process for GC analysis or the injection mode, were also investigated for the same purpose. A comparative study of different methods used for the calculation of the limits of detection was also performed, in order to compare them in terms of the obtained values and their veracity. Differences found in the results obtained with different configurations showed different limits of detection and different precision. These results allowed us to indicate advantages and limitations, which depended on the configuration of the GC-MS used. Finally, differences up to seven orders of magnitude were found in the LOD values obtained with different methods, some of them being too small to show any measurable peak.Instituto Universitario de Investigación en Ciencias PolicialesUniversidad de Alcalá20172017-04-12journal articlehttp://purl.org/coar/resource_type/c_6501NAhttp://purl.org/coar/version/c_be7fb7dd8ff6fe43info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10017/48607https://dx.doi.org/10.1039/C7AY00813Areponame:e_Buah Biblioteca Digital Universidad de Alcaláinstname:Universidad de Alcalá (UAH)InglésengIUICP Not available IUICP-2016-003 Screening (cribado) de tóxicos mediante cromatografía líquida acoplada a espectrometría de masas con analizador de cuadrupolo y trampa (LC-Q-TRAP-MS) en muestras de sangre total-plasma-sueroopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:ebuah.uah.es:10017/486072026-06-18T11:13:07Z |
| dc.title.none.fl_str_mv |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites |
| title |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites |
| spellingShingle |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites Saiz Galindo, Jorge GC-MS Cocaine Heroin Cannabis Opioids Química Chemistry |
| title_short |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites |
| title_full |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites |
| title_fullStr |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites |
| title_full_unstemmed |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites |
| title_sort |
Comparison of different GC-MS configurations for the determination of prevalent drugs and related metabolites |
| dc.creator.none.fl_str_mv |
Saiz Galindo, Jorge García Ruiz, Carmen|||0000-0001-5925-3449 Gómara Moreno, Belén |
| author |
Saiz Galindo, Jorge |
| author_facet |
Saiz Galindo, Jorge García Ruiz, Carmen|||0000-0001-5925-3449 Gómara Moreno, Belén |
| author_role |
author |
| author2 |
García Ruiz, Carmen|||0000-0001-5925-3449 Gómara Moreno, Belén |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
GC-MS Cocaine Heroin Cannabis Opioids Química Chemistry |
| topic |
GC-MS Cocaine Heroin Cannabis Opioids Química Chemistry |
| description |
Cocaine, cannabis, heroin, and other opioids are among the prevalent drugs in Europe. The use of these drugs is demonstrated by the determination of either parent drugs or related metabolites in a variety of biological samples. Various analytical methodologies can be applied for this purpose, all of which might show relevant differences in analytical performance. In this work we used different GC-MS configurations for the quantitation of cocaine, cocaethylene, benzoylecgonine, morphine, and Delta9-tetrahydrocannabinol with the aim of comparing the analytical performance of different GC-MS instruments, different injectors, ion sources, ionization modes, mass analyzers, operating modes, and acquisition modes, in order to find the optimal configuration in terms of sensitivity and precision. Other important factors, such as the derivatization process for GC analysis or the injection mode, were also investigated for the same purpose. A comparative study of different methods used for the calculation of the limits of detection was also performed, in order to compare them in terms of the obtained values and their veracity. Differences found in the results obtained with different configurations showed different limits of detection and different precision. These results allowed us to indicate advantages and limitations, which depended on the configuration of the GC-MS used. Finally, differences up to seven orders of magnitude were found in the LOD values obtained with different methods, some of them being too small to show any measurable peak. |
| publishDate |
2017 |
| dc.date.none.fl_str_mv |
2017 2017-04-12 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 NA http://purl.org/coar/version/c_be7fb7dd8ff6fe43 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10017/48607 https://dx.doi.org/10.1039/C7AY00813A |
| url |
http://hdl.handle.net/10017/48607 https://dx.doi.org/10.1039/C7AY00813A |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.relation.none.fl_str_mv |
IUICP Not available IUICP-2016-003 Screening (cribado) de tóxicos mediante cromatografía líquida acoplada a espectrometría de masas con analizador de cuadrupolo y trampa (LC-Q-TRAP-MS) en muestras de sangre total-plasma-suero |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:e_Buah Biblioteca Digital Universidad de Alcalá instname:Universidad de Alcalá (UAH) |
| instname_str |
Universidad de Alcalá (UAH) |
| reponame_str |
e_Buah Biblioteca Digital Universidad de Alcalá |
| collection |
e_Buah Biblioteca Digital Universidad de Alcalá |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869418729717104640 |
| score |
15,198674 |