Low toxicity deep eutectic solvent-based ferrofluid for the determination of UV filters in environmental waters by stir bar dispersive liquid microextraction.

[EN] In this work, a low toxicity deep eutectic solvent-based ferrofluid is presented for the first time as magnetic fluid to be used as an efficient solvent in liquid-based microextraction techniques. This ferrofluid is made of a hydrophobic deep eutectic solvent, composed by menthol and thymol in...

ver descrição completa

Detalhes bibliográficos
Autores: Duque Calvo, Alaine, Grau, José, Benedé, Juan Luis, Alonso Rojas, Rosa María, Campanero, Miguel Ángel, Chisvert, Alberto
Tipo de documento: artigo
Data de publicação:2022
País:España
Recursos:Universidad del País Vasco
Repositório:Addi. Archivo Digital para la Docencia y la Investigación
OAI Identifier:oai:addi.ehu.eus:10810/56721
Acesso em linha:http://hdl.handle.net/10810/56721
Access Level:Acceso aberto
Palavra-chave:deep eutectic solvent
ferrofluid
liquid chromatography-tandem mass spectrometry
stir bar dispersive liquid microextraction
UV filters
water samples
Descrição
Resumo:[EN] In this work, a low toxicity deep eutectic solvent-based ferrofluid is presented for the first time as magnetic fluid to be used as an efficient solvent in liquid-based microextraction techniques. This ferrofluid is made of a hydrophobic deep eutectic solvent, composed by menthol and thymol in a 1:5 molar ratio as carrier solvent, and oleic acid-coated cobalt ferrite (CoFe2O4@oleic acid) magnetic nanoparticles. This material was characterized via magnetism measurement, scanning electron microscopy, infrared spectroscopy and density measurement. The determination of UV filters in environmental water samples was selected as model analytical application to test the extraction performance of this new ferrofluid by employing stir bar dispersive liquid microextraction, prior to liquid chromatography-tandem mass spectrometry analysis. The response surface methodology was used as a multivariate optimization method for extraction step. Under the optimized conditions, good analytical features were obtained, such as low limits of detection between 7 and 83ngL-1, good repeatability (relative standard deviations, RSD (%) below 15%), enrichment factors between 46 and 101 and relative recoveries between 80 and 117%, proving the good extraction capability of this ferrofluid. Finally, the method was successfully applied to three environmental waters (beach and river waters), finding trace amounts of the target UV filters. The presented low toxicity deep eutectic solvent-based ferrofluid results to be a good alternative to conventional solvents used in liquid-phase microextraction techniques.