Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform
Objectives: To assess the potential influence of the ratio between the storage tube surface area and the volume of cerebrospinal fluid (CSF) (surface/volume) on the quantifications of four Alzheimer's disease (AD) biomarkers on the Lumipulse G600II automated platform. Methods: CSF samples of 10...
| Autores: | , , , , , , , |
|---|---|
| Tipo de documento: | artigo |
| Estado: | Versão publicada |
| Data de publicação: | 2019 |
| País: | España |
| Recursos: | Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau) |
| Repositório: | r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau |
| OAI Identifier: | oai:iibsantpau.fundanetsuite.com:p2966 |
| Acesso em linha: | https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=2966 https://hal.umontpellier.fr/hal-02626119 |
| Access Level: | Acceso aberto |
| Palavra-chave: | Cerebrospinal fluid Biomarkers Amyloid Tau Lumipulse Alzheimer's disease |
| id |
ES_acd967b0227fbdff2a8d1e9dd07154c6 |
|---|---|
| oai_identifier_str |
oai:iibsantpau.fundanetsuite.com:p2966 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platformDelaby, CMunoz, LTorres, SNadal, ALe Bastard, NLehmann, SLleo, AAlcolea, DCerebrospinal fluidBiomarkersAmyloidTauLumipulseAlzheimer's diseaseObjectives: To assess the potential influence of the ratio between the storage tube surface area and the volume of cerebrospinal fluid (CSF) (surface/volume) on the quantifications of four Alzheimer's disease (AD) biomarkers on the Lumipulse G600II automated platform. Methods: CSF samples of 10 consecutive patients were stored in 2 ml polypropylene tubes containing four different CSF volumes: 1.5 ml, 1 ml, 0.5 ml and 0.25 ml. Concentration of CSF A beta 1-42, A beta 1-40, t-Tau and p-Tau were measured in all aliquots using the LUMIPULSE G600II automated platform from Fujirebio. Results: Levels of CSF A beta 1-42 and A beta 1-40 were lower in samples stored with lower volumes (higher surface/volume ratios). This decrease was partly compensated by using the ratio A beta 1-42/A beta 1-40. Quantification of t-Tau and p-Tau were not influenced by this pre-analytical condition. Conclusion: The surface/volume ratio can potentially influence the results of amyloid AD biomarkers. It appears essential to take into account the surface/volume ratio of the storage tubes when quantifying CSF biomarkers in clinical routine.ELSEVIER2019info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=2966https://hal.umontpellier.fr/hal-02626119CLINICA CHIMICA ACTAISSN: 00098981ISSNe: 18733492reponame:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pauinstname:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)Inglésinfo:eu-repo/semantics/openAccessoai:iibsantpau.fundanetsuite.com:p29662026-06-14T12:41:47Z |
| dc.title.none.fl_str_mv |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform |
| title |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform |
| spellingShingle |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform Delaby, C Cerebrospinal fluid Biomarkers Amyloid Tau Lumipulse Alzheimer's disease |
| title_short |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform |
| title_full |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform |
| title_fullStr |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform |
| title_full_unstemmed |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform |
| title_sort |
Impact of CSF storage volume on the analysis of Alzheimer's disease biomarkers on an automated platform |
| dc.creator.none.fl_str_mv |
Delaby, C Munoz, L Torres, S Nadal, A Le Bastard, N Lehmann, S Lleo, A Alcolea, D |
| author |
Delaby, C |
| author_facet |
Delaby, C Munoz, L Torres, S Nadal, A Le Bastard, N Lehmann, S Lleo, A Alcolea, D |
| author_role |
author |
| author2 |
Munoz, L Torres, S Nadal, A Le Bastard, N Lehmann, S Lleo, A Alcolea, D |
| author2_role |
author author author author author author author |
| dc.subject.none.fl_str_mv |
Cerebrospinal fluid Biomarkers Amyloid Tau Lumipulse Alzheimer's disease |
| topic |
Cerebrospinal fluid Biomarkers Amyloid Tau Lumipulse Alzheimer's disease |
| description |
Objectives: To assess the potential influence of the ratio between the storage tube surface area and the volume of cerebrospinal fluid (CSF) (surface/volume) on the quantifications of four Alzheimer's disease (AD) biomarkers on the Lumipulse G600II automated platform. Methods: CSF samples of 10 consecutive patients were stored in 2 ml polypropylene tubes containing four different CSF volumes: 1.5 ml, 1 ml, 0.5 ml and 0.25 ml. Concentration of CSF A beta 1-42, A beta 1-40, t-Tau and p-Tau were measured in all aliquots using the LUMIPULSE G600II automated platform from Fujirebio. Results: Levels of CSF A beta 1-42 and A beta 1-40 were lower in samples stored with lower volumes (higher surface/volume ratios). This decrease was partly compensated by using the ratio A beta 1-42/A beta 1-40. Quantification of t-Tau and p-Tau were not influenced by this pre-analytical condition. Conclusion: The surface/volume ratio can potentially influence the results of amyloid AD biomarkers. It appears essential to take into account the surface/volume ratio of the storage tubes when quantifying CSF biomarkers in clinical routine. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=2966 https://hal.umontpellier.fr/hal-02626119 |
| url |
https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=2966 https://hal.umontpellier.fr/hal-02626119 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
ELSEVIER |
| publisher.none.fl_str_mv |
ELSEVIER |
| dc.source.none.fl_str_mv |
CLINICA CHIMICA ACTA ISSN: 00098981 ISSNe: 18733492 reponame:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau instname:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau) |
| instname_str |
Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau) |
| reponame_str |
r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau |
| collection |
r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869416389558665216 |
| score |
15,812455 |