Flexible Trilinearity Alignment (FTA) and Shift Invariant Transformation (SIT) Constraints in Three-Way Multivariate Curve Resolution Data Analysis

In this work, two alternative ways of analyzing three-way data with multivariate curve resolution alternating least squares (MCR-ALS) using the trilinearity constraint are described and compared. Different synthetic datasets and experimental three-way datasets covering different scenarios are analyz...

Descripción completa

Detalles Bibliográficos
Autores: Zhang, Xin, Tauler, Romà
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Institución:Consejo Superior de Investigaciones Científicas (CSIC)
Repositorio:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/366791
Acceso en línea:http://hdl.handle.net/10261/366791
https://api.elsevier.com/content/abstract/scopus_id/85200763645
Access Level:acceso abierto
Palabra clave:Trilinearity
Flexible trilinearity alignment (FTA)
MCR-ALS
Shift invariant transformation (SIT)
Three-way data
http://metadata.un.org/sdg/11
http://metadata.un.org/sdg/3
Ensure healthy lives and promote well-being for all at all ages
Make cities and human settlements inclusive, safe, resilient and sustainable
Descripción
Sumario:In this work, two alternative ways of analyzing three-way data with multivariate curve resolution alternating least squares (MCR-ALS) using the trilinearity constraint are described and compared. Different synthetic datasets and experimental three-way datasets covering different scenarios are analyzed, and the results obtained are compared. The two new different ways of applying the trilinearity constraint are named flexible trilinearity alignment (FTA) and shift invariant transformation (SIT). The effects of noise in the application of both types of constraints are investigated in detail. Results show that both approaches are particularly adequate for those cases like in gas chromatography and especially in liquid chromatography where the elution profiles of the same chemical component in different chromatographic runs are not totally reproducible because they are time shifted, although they preserve their shape. When strong time shifts and co-elution occur, then the “standard” trilinear model does not work, and alternative approaches should be used, such as the MCR extended bilinear model to multiset (multirun) data, or the proposed relaxation of the trilinearity constraint in the FTA and SIT methods to capture the time drift changes produced in the elution profiles of the resolved components.