Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation

Purpose: The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a...

Full description

Bibliographic Details
Authors: Beltrán Murcia, J., Álvarez-Rementería Capelo, Laureano, Blázquez Sánchez, V
Format: article
Publication Date:2025
Country:España
Institution:Universidad Complutense de Madrid (UCM)
Repository:Docta Complutense
Language:English
OAI Identifier:oai:docta.ucm.es:20.500.14352/122568
Online Access:https://hdl.handle.net/20.500.14352/122568
Access Level:Open access
Keyword:617.7-089.243
Endothelium-ICL
EVO ICL
Implantable Collamer lens
Phakic lens
Vault
Oftalmología
3201.09 Oftalmología
Description
Summary:Purpose: The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. Methods: In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. Results: 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively (p = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. Conclusions: The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.