Assessment of a Universal Reconfiguration-less Control Approach in Open-Phase Fault Operation for Multiphase Drives

Multiphase drives have been important in particular industry applications where reliability is a desired goal. The main reason for this is their inherent fault tolerance. Di erent nonlinear controllers that do not include modulation stages, like direct torque control (DTC) or model-based predictive...

ver descrição completa

Detalhes bibliográficos
Autores: Barrero, Federico, Bermúdez, Mario, Durán, Mario J., Salas, Pedro, González Prieto, Ignacio
Formato: artículo
Fecha de publicación:2019
País:España
Recursos:Universidad de Huelva (UHU)
Repositorio:Arias Montano. Repositorio Institucional de la Universidad de Huelva
Idioma:inglés
OAI Identifier:oai:ariasmontano.uhu.es:10272/17611
Acesso em linha:http://hdl.handle.net/10272/17611
Access Level:acceso abierto
Palavra-chave:Multiphase induction motor drives
Natural fault tolerance
Virtual voltage vectors
Descrição
Resumo:Multiphase drives have been important in particular industry applications where reliability is a desired goal. The main reason for this is their inherent fault tolerance. Di erent nonlinear controllers that do not include modulation stages, like direct torque control (DTC) or model-based predictive control (MPC), have been used in recent times to govern these complex systems, including mandatory control reconfiguration to guarantee the fault tolerance characteristic. A new reconfiguration-less approach based on virtual voltage vectors (VVs) was recently proposed for MPC, providing a natural healthy and faulty closed-loop regulation of a particular asymmetrical six-phase drive. This work validates the interest in the reconfiguration-less approach for direct controllers and multiphase drives.