3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors

One of the major difficulties in the development of evanescent wave optical fiber sensors (EWOFS) lies in the complexity of the manufacturing of the chemosensitive element, particularly when using plastic optical fibers (POFs). While these fibers are appealing waveguides thanks to their low cost, ea...

ver descrição completa

Detalhes bibliográficos
Autores: Darder Amengual, María Del Mar, Serrano, Luis, Bedoya, Maximino, Orellana Moraleda, Guillermo
Tipo de documento: artigo
Data de publicação:2022
País:España
Recursos:Universidad Complutense de Madrid (UCM)
Repositório:Docta Complutense
Idioma:inglês
OAI Identifier:oai:docta.ucm.es:20.500.14352/72317
Acesso em linha:https://hdl.handle.net/20.500.14352/72317
Access Level:Acceso aberto
Palavra-chave:547
3D printing filaments
plastic optical fiber
evanescent wave
formaldehyde sensor
Química orgánica (Química)
2306 Química Orgánica
id ES_8d4c883eca82e35c06cc8588037a69cb
oai_identifier_str oai:docta.ucm.es:20.500.14352/72317
network_acronym_str ES
network_name_str España
repository_id_str
spelling 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) ChemosensorsDarder Amengual, María Del MarSerrano, LuisBedoya, MaximinoOrellana Moraleda, Guillermo5473D printing filamentsplastic optical fiberevanescent waveformaldehyde sensorQuímica orgánica (Química)2306 Química OrgánicaOne of the major difficulties in the development of evanescent wave optical fiber sensors (EWOFS) lies in the complexity of the manufacturing of the chemosensitive element, particularly when using plastic optical fibers (POFs). While these fibers are appealing waveguides thanks to their low cost, ease of connectorization and robustness, the need for removing the cladding material complicates the EWOFS fabrication. In this paper we discuss how 3D printing filaments can serve as an alternative to commercially available POF for the development of EWOFS. In the process of replacing the traditional POF, we compared the performance of two EWOFS for monitoring airborne formaldehyde. These sensitive elements were manufactured either from 1.75 mm diameter 3D printing filaments, or from a commercially available POF. After the optimization of their respective fabrication protocols, the analytical performance of the two formaldehyde EWOFS was compared in terms of sensitivity and reproducibility. In this regard, the easy-to-manufacture 3D printing filament-based waveguides provided 5-fold lower detection limits with respect to the commercial POF-based sensors. Although no statistically significant differences were found in terms of reproducibility, the simplification of the sensor manufacturing process together with the increased analytical performance for chemical sensing spur the use of 3D printing filaments for the development of new POF-based EWOFS.MDPIUniversidad Complutense de Madrid20222022-01-0120222022-01-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/72317reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Atribución 3.0 Españahttps://creativecommons.org/licenses/by/3.0/es/info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/723172026-06-02T12:44:21Z
dc.title.none.fl_str_mv 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors
title 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors
spellingShingle 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors
Darder Amengual, María Del Mar
547
3D printing filaments
plastic optical fiber
evanescent wave
formaldehyde sensor
Química orgánica (Química)
2306 Química Orgánica
title_short 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors
title_full 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors
title_fullStr 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors
title_full_unstemmed 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors
title_sort 3D Printing Filaments Facilitate the Development of Evanescent Wave Plastic Optical Fiber (POF) Chemosensors
dc.creator.none.fl_str_mv Darder Amengual, María Del Mar
Serrano, Luis
Bedoya, Maximino
Orellana Moraleda, Guillermo
author Darder Amengual, María Del Mar
author_facet Darder Amengual, María Del Mar
Serrano, Luis
Bedoya, Maximino
Orellana Moraleda, Guillermo
author_role author
author2 Serrano, Luis
Bedoya, Maximino
Orellana Moraleda, Guillermo
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidad Complutense de Madrid
dc.subject.none.fl_str_mv 547
3D printing filaments
plastic optical fiber
evanescent wave
formaldehyde sensor
Química orgánica (Química)
2306 Química Orgánica
topic 547
3D printing filaments
plastic optical fiber
evanescent wave
formaldehyde sensor
Química orgánica (Química)
2306 Química Orgánica
description One of the major difficulties in the development of evanescent wave optical fiber sensors (EWOFS) lies in the complexity of the manufacturing of the chemosensitive element, particularly when using plastic optical fibers (POFs). While these fibers are appealing waveguides thanks to their low cost, ease of connectorization and robustness, the need for removing the cladding material complicates the EWOFS fabrication. In this paper we discuss how 3D printing filaments can serve as an alternative to commercially available POF for the development of EWOFS. In the process of replacing the traditional POF, we compared the performance of two EWOFS for monitoring airborne formaldehyde. These sensitive elements were manufactured either from 1.75 mm diameter 3D printing filaments, or from a commercially available POF. After the optimization of their respective fabrication protocols, the analytical performance of the two formaldehyde EWOFS was compared in terms of sensitivity and reproducibility. In this regard, the easy-to-manufacture 3D printing filament-based waveguides provided 5-fold lower detection limits with respect to the commercial POF-based sensors. Although no statistically significant differences were found in terms of reproducibility, the simplification of the sensor manufacturing process together with the increased analytical performance for chemical sensing spur the use of 3D printing filaments for the development of new POF-based EWOFS.
publishDate 2022
dc.date.none.fl_str_mv 2022
2022-01-01
2022
2022-01-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/20.500.14352/72317
url https://hdl.handle.net/20.500.14352/72317
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 3.0 España
https://creativecommons.org/licenses/by/3.0/es/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 3.0 España
https://creativecommons.org/licenses/by/3.0/es/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Docta Complutense
instname:Universidad Complutense de Madrid (UCM)
instname_str Universidad Complutense de Madrid (UCM)
reponame_str Docta Complutense
collection Docta Complutense
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869413034089250816
score 15.228081