Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA

Background: The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and...

ver descrição completa

Detalhes bibliográficos
Autores: Iglesias, María, Kudsieh, Bachar, Laiseca, Andrea, Santos, Cristina, Nadal Reus, Jeroni, Barraquer, Rafael, Casaroli Marano, Ricardo Pedro
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2022
País:España
Recursos:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:2445/183734
Acesso em linha:https://hdl.handle.net/2445/183734
Access Level:acceso abierto
Palavra-chave:Tonometria
Miopia
Tonometry
Myopia
id ES_8cf0b126a6c464535f6beb2be277a9b2
oai_identifier_str oai:recercat.cat:2445/183734
network_acronym_str ES
network_name_str España
repository_id_str
spelling Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORAIglesias, MaríaKudsieh, BacharLaiseca, AndreaSantos, CristinaNadal Reus, JeroniBarraquer, RafaelCasaroli Marano, Ricardo PedroTonometriaMiopiaTonometryMyopiaBackground: The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA). Methods: Prospective double-masked study performed on thirty eyes of thirty patients that underwent laser in situ keratomileusis (LASIK; n = 19) or photorefractive keratectomy (PRK; n = 11). IOP was measured before and 3 and 12 months after surgery. Intraclass correlation coefficient (ICC) and Bland-Altman plot were calculated to assess the agreement between GAT, CT, IOPg (Goldmann-correlated IOP) and IOPcc (corneal-compensated IOP) from ORA. Results: Twelve months after LASIK, IOP measured with CT showed the best correlation with IOP measured with GAT before surgery (GATpre) (ICC = 0.886, 95% CI: 0.703-0.956) (15.60 ± 3.27 vs 15.80 ± 3.22; p < 0.000). However, a moderate correlation was found for IOP measured with IOPcc and CT 12 months after LASIK (ICC = 0.568, 95% CI: − 0.185 - 0.843) (15.80 ± 3.22 vs 12.87 ± 2.77; p < 0.004). Twelve months after PRK, CT showed a weak correlation (ICC = − 0.266, 95% CI: − 3.896 - 0.663), compared to GATpre (17.30 ± 3.47 vs 16.01 ± 1.45; p < 0.642), as well as poor correlation (ICC = 0.256, 95% CI: − 0.332 - 0.719) with IOPcc (17.30 ± 3.47 vs 13.38 ± 1.65; p < 0.182). Conclusions: Twelve months after LASIK, IOP measured with CT strongly correlated with GAT before surgery and could therefore provide an alternative method for measuring IOP after this surgery. More studies regarding this new convex prism are needed to assess its accuracy. Keywords: Tonometry, Corneal biomechanics, Intraocular pressure, Glaucoma, Myopia, LASIK, PRKBioMed Central2022202220222022info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion9 p.application/pdfhttps://hdl.handle.net/2445/183734Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésReproducció del document publicat a: https://doi.org/10.1186/s12886-022-02309-xBMC Ophthalmology, 2022, vol. 22, num. 1, p. 79https://doi.org/10.1186/s12886-022-02309-xcc-by (c) Iglesias, María et al., 2022https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:recercat.cat:2445/1837342026-05-29T05:05:01Z
dc.title.none.fl_str_mv Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
spellingShingle Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
Iglesias, María
Tonometria
Miopia
Tonometry
Myopia
title_short Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title_full Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title_fullStr Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title_full_unstemmed Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
title_sort Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism: correlations with GAT and ORA
dc.creator.none.fl_str_mv Iglesias, María
Kudsieh, Bachar
Laiseca, Andrea
Santos, Cristina
Nadal Reus, Jeroni
Barraquer, Rafael
Casaroli Marano, Ricardo Pedro
author Iglesias, María
author_facet Iglesias, María
Kudsieh, Bachar
Laiseca, Andrea
Santos, Cristina
Nadal Reus, Jeroni
Barraquer, Rafael
Casaroli Marano, Ricardo Pedro
author_role author
author2 Kudsieh, Bachar
Laiseca, Andrea
Santos, Cristina
Nadal Reus, Jeroni
Barraquer, Rafael
Casaroli Marano, Ricardo Pedro
author2_role author
author
author
author
author
author
dc.subject.none.fl_str_mv Tonometria
Miopia
Tonometry
Myopia
topic Tonometria
Miopia
Tonometry
Myopia
description Background: The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA). Methods: Prospective double-masked study performed on thirty eyes of thirty patients that underwent laser in situ keratomileusis (LASIK; n = 19) or photorefractive keratectomy (PRK; n = 11). IOP was measured before and 3 and 12 months after surgery. Intraclass correlation coefficient (ICC) and Bland-Altman plot were calculated to assess the agreement between GAT, CT, IOPg (Goldmann-correlated IOP) and IOPcc (corneal-compensated IOP) from ORA. Results: Twelve months after LASIK, IOP measured with CT showed the best correlation with IOP measured with GAT before surgery (GATpre) (ICC = 0.886, 95% CI: 0.703-0.956) (15.60 ± 3.27 vs 15.80 ± 3.22; p < 0.000). However, a moderate correlation was found for IOP measured with IOPcc and CT 12 months after LASIK (ICC = 0.568, 95% CI: − 0.185 - 0.843) (15.80 ± 3.22 vs 12.87 ± 2.77; p < 0.004). Twelve months after PRK, CT showed a weak correlation (ICC = − 0.266, 95% CI: − 3.896 - 0.663), compared to GATpre (17.30 ± 3.47 vs 16.01 ± 1.45; p < 0.642), as well as poor correlation (ICC = 0.256, 95% CI: − 0.332 - 0.719) with IOPcc (17.30 ± 3.47 vs 13.38 ± 1.65; p < 0.182). Conclusions: Twelve months after LASIK, IOP measured with CT strongly correlated with GAT before surgery and could therefore provide an alternative method for measuring IOP after this surgery. More studies regarding this new convex prism are needed to assess its accuracy. Keywords: Tonometry, Corneal biomechanics, Intraocular pressure, Glaucoma, Myopia, LASIK, PRK
publishDate 2022
dc.date.none.fl_str_mv 2022
2022
2022
2022
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/2445/183734
url https://hdl.handle.net/2445/183734
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Reproducció del document publicat a: https://doi.org/10.1186/s12886-022-02309-x
BMC Ophthalmology, 2022, vol. 22, num. 1, p. 79
https://doi.org/10.1186/s12886-022-02309-x
dc.rights.none.fl_str_mv cc-by (c) Iglesias, María et al., 2022
https://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv cc-by (c) Iglesias, María et al., 2022
https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 9 p.
application/pdf
dc.publisher.none.fl_str_mv BioMed Central
publisher.none.fl_str_mv BioMed Central
dc.source.none.fl_str_mv Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
reponame:Recercat. Dipósit de la Recerca de Catalunya
instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
reponame_str Recercat. Dipósit de la Recerca de Catalunya
collection Recercat. Dipósit de la Recerca de Catalunya
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869412973760479232
score 15,812455