Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors
This work reports for the first time an electrochemical immunosensor for the determination of adrenocorticotropin hormone (ACTH). The immunoelectrode design involves the use of amino phenylboronic acid for the oriented immobilization of anti-ACTH antibodies onto screen-printed carbon modified electr...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2012 |
| País: | España |
| Institución: | Universidad Complutense de Madrid (UCM) |
| Repositorio: | Docta Complutense |
| Idioma: | inglés |
| OAI Identifier: | oai:docta.ucm.es:20.500.14352/42874 |
| Acceso en línea: | https://hdl.handle.net/20.500.14352/42874 |
| Access Level: | acceso abierto |
| Palabra clave: | 543 Adrenocorticotropin hormone Phenyl boronic acid Electrochemical immunosensor Química analítica (Química) 2301 Química Analítica |
| id |
ES_8a6b3b571a40c9ada6e176d5caebe9bb |
|---|---|
| oai_identifier_str |
oai:docta.ucm.es:20.500.14352/42874 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensorsMoreno Guzmán, MaríaVillalonga Santana, ReynaldoOjeda Fernández, IreneGonzález Cortés, AraceliYáñez-Sedeño Orive, PalomaPingarrón Carrazón, José Manuel543Adrenocorticotropin hormonePhenyl boronic acidElectrochemical immunosensorQuímica analítica (Química)2301 Química AnalíticaThis work reports for the first time an electrochemical immunosensor for the determination of adrenocorticotropin hormone (ACTH). The immunoelectrode design involves the use of amino phenylboronic acid for the oriented immobilization of anti-ACTH antibodies onto screen-printed carbon modified electrode surfaces. A competitive immunoassay between the antigen and the biotinylated hormone for the binding sites of the immobilized antibody was performed. The electroanalytical response was generated by using alkaline phosphatase-labelled streptavidin and 1-naphtyl phosphate as the enzyme substrate. The electrochemical oxidation of the enzyme reaction product, 1-naphtol, measured by differential pulse voltammetry was employed to monitor the affinity reaction. Under the optimized working conditions, an extremely low detection limit of 18 pg/L was obtained. Cross-reactivity was evaluated against other hormones (cortisol, estradiol, testosterone, progesterone, hGH and prolactin) and the obtained results demonstrated an excellent selectivity. The developed immunosensor was applied to a human serum sample containing a certified amount of ACTH with good results.ElsevierUniversidad Complutense de Madrid20122012-01-0120122012-01-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/42874reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Atribución-NoComercial-SinDerivadas 3.0 Españahttps://creativecommons.org/licenses/by-nc-nd/3.0/es/info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/428742026-06-02T12:44:21Z |
| dc.title.none.fl_str_mv |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors |
| title |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors |
| spellingShingle |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors Moreno Guzmán, María 543 Adrenocorticotropin hormone Phenyl boronic acid Electrochemical immunosensor Química analítica (Química) 2301 Química Analítica |
| title_short |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors |
| title_full |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors |
| title_fullStr |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors |
| title_full_unstemmed |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors |
| title_sort |
Ultrasensitive detection of adrenocorticotropin hormone (ACTH) using disposable phenylboronic-modified electrochemical immunosensors |
| dc.creator.none.fl_str_mv |
Moreno Guzmán, María Villalonga Santana, Reynaldo Ojeda Fernández, Irene González Cortés, Araceli Yáñez-Sedeño Orive, Paloma Pingarrón Carrazón, José Manuel |
| author |
Moreno Guzmán, María |
| author_facet |
Moreno Guzmán, María Villalonga Santana, Reynaldo Ojeda Fernández, Irene González Cortés, Araceli Yáñez-Sedeño Orive, Paloma Pingarrón Carrazón, José Manuel |
| author_role |
author |
| author2 |
Villalonga Santana, Reynaldo Ojeda Fernández, Irene González Cortés, Araceli Yáñez-Sedeño Orive, Paloma Pingarrón Carrazón, José Manuel |
| author2_role |
author author author author author |
| dc.contributor.none.fl_str_mv |
Universidad Complutense de Madrid |
| dc.subject.none.fl_str_mv |
543 Adrenocorticotropin hormone Phenyl boronic acid Electrochemical immunosensor Química analítica (Química) 2301 Química Analítica |
| topic |
543 Adrenocorticotropin hormone Phenyl boronic acid Electrochemical immunosensor Química analítica (Química) 2301 Química Analítica |
| description |
This work reports for the first time an electrochemical immunosensor for the determination of adrenocorticotropin hormone (ACTH). The immunoelectrode design involves the use of amino phenylboronic acid for the oriented immobilization of anti-ACTH antibodies onto screen-printed carbon modified electrode surfaces. A competitive immunoassay between the antigen and the biotinylated hormone for the binding sites of the immobilized antibody was performed. The electroanalytical response was generated by using alkaline phosphatase-labelled streptavidin and 1-naphtyl phosphate as the enzyme substrate. The electrochemical oxidation of the enzyme reaction product, 1-naphtol, measured by differential pulse voltammetry was employed to monitor the affinity reaction. Under the optimized working conditions, an extremely low detection limit of 18 pg/L was obtained. Cross-reactivity was evaluated against other hormones (cortisol, estradiol, testosterone, progesterone, hGH and prolactin) and the obtained results demonstrated an excellent selectivity. The developed immunosensor was applied to a human serum sample containing a certified amount of ACTH with good results. |
| publishDate |
2012 |
| dc.date.none.fl_str_mv |
2012 2012-01-01 2012 2012-01-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/20.500.14352/42874 |
| url |
https://hdl.handle.net/20.500.14352/42874 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Atribución-NoComercial-SinDerivadas 3.0 España https://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Atribución-NoComercial-SinDerivadas 3.0 España https://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:Docta Complutense instname:Universidad Complutense de Madrid (UCM) |
| instname_str |
Universidad Complutense de Madrid (UCM) |
| reponame_str |
Docta Complutense |
| collection |
Docta Complutense |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869412715032739840 |
| score |
15,301629 |