Characterization of Dysphagia Thickeners Using Texture Analysis-What Information Can Be Useful?

Besides shear viscosity, other texture parameters (adhesiveness or cohesiveness) might be relevant for safe swallowing in people suffering from oropharyngeal dysphagia. Shear viscosity is assessed through protocols developed using a viscometer or a rheometer. In contrast, protocols and instruments (...

ver descrição completa

Detalhes bibliográficos
Autores: Baixauli, Raquel, Bolivar-Prados, Mireia|||0000-0002-8896-1150, Ismael-Mohammed, Kovan|||0000-0001-5786-0237, Clavé i Civit, Pere|||0000-0002-0696-8560, Tárrega, Amparo|||0000-0003-3338-2204, Laguna, Laura|||0000-0001-8551-1886
Tipo de documento: artigo
Data de publicação:2022
País:España
Recursos:Universitat Autònoma de Barcelona
Repositório:Dipòsit Digital de Documents de la UAB
Idioma:inglês
OAI Identifier:oai:ddd.uab.cat:292418
Acesso em linha:https://ddd.uab.cat/record/292418
https://dx.doi.org/urn:doi:10.3390/gels8070430
Access Level:Acceso aberto
Palavra-chave:Dysphagia
Texture analyzer
Thickener
Descrição
Resumo:Besides shear viscosity, other texture parameters (adhesiveness or cohesiveness) might be relevant for safe swallowing in people suffering from oropharyngeal dysphagia. Shear viscosity is assessed through protocols developed using a viscometer or a rheometer. In contrast, protocols and instruments (capillary break-up rheometer) to assess adhesiveness and cohesiveness are less common and much less developed. Other equipment such as texture analyzers can provide useful information on food properties. Here, we aimed to explore different texture analyzer settings (type of test, probe, and protocol) to characterize four commercial dysphagia thickeners at the shear viscosity levels recommended by manufacturers. Among the tests used (extrusion or penetration) with the different probes (disc, cone and shape holder, sphere, or cylinder), cone extrusion provided information about adhesivity, disc extrusion about sample cohesiveness, and sphere about penetration and sample elasticity. The test speeds used influenced the results, but only one speed is needed as the different speeds provided the same fluid information; for easiness, it is proposed to use 1 mm/s. Comparing the texture analyzer results with viscosity values obtained at different shears, the texture analyzer parameters reflected information that differ from shear viscosity. This information could be relevant for the therapeutic effect of thickening products and food characterization.