The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain
Residential heritage buildings in the Mediterranean region face unexpected challenges in the field of energy efficiency and indoor environmental quality to ensure the sustainable conservation of historic town centres. This paper evaluates whether the conservation of their values can coexist with the...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Estado: | Versión aceptada para publicación |
| Fecha de publicación: | 2021 |
| País: | España |
| Recursos: | Universidad de Sevilla (US) |
| Repositorio: | idUS. Depósito de Investigación de la Universidad de Sevilla |
| OAI Identifier: | oai:idus.us.es:11441/150709 |
| Acesso em linha: | https://hdl.handle.net/11441/150709 https://doi.org/10.1016/j.enbuild.2021.111302 |
| Access Level: | acceso abierto |
| Palavra-chave: | Heritage housing Built heritage decarbonization Energy retrofit RES building integration Hybrid energy system Thermal comfort |
| id |
ES_6cb737d26062c8aa9e8ff6cb984e58df |
|---|---|
| oai_identifier_str |
oai:idus.us.es:11441/150709 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, SpainCaro Martínez, Rosa AnaSendra, Juan J.Muñoz González, Carmen MaríaHeritage housingBuilt heritage decarbonizationEnergy retrofitRES building integrationHybrid energy systemThermal comfortResidential heritage buildings in the Mediterranean region face unexpected challenges in the field of energy efficiency and indoor environmental quality to ensure the sustainable conservation of historic town centres. This paper evaluates whether the conservation of their values can coexist with the current energy efficiency requirements and be included in urban decarbonization plans to prevent neglect and degradation. For this, a comprehensive decarbonization plan was drawn up based on the results of a previous energy audit on the case study selected, an 18th-century listed residential building in Seville, Spain. Envelope improvement was combined with mechanical ventilation and an integrated heat pump combining RESs and electricity from the public grid to cover all thermal needs in order to reach NZEB performance in the building. Despite the complexity of integrating demanding energy efficiency standards into heritage buildings, which requires case-by-case analysis and dynamic simulation, findings show a notable degree of approximation to NZEB performance. The main obstacles stem from the large amount of energy consumed by auxiliary systems and the relatively low presence of RESs in the national electricity mix.ElsevierConstrucciones Arquitectónicas ITEP130: Arquitectura, Patrimonio y Sostenibilidad: Acústica, Iluminación, Óptica y Energía2021info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionapplication/pdfapplication/pdfhttps://hdl.handle.net/11441/150709https://doi.org/10.1016/j.enbuild.2021.111302reponame:idUS. Depósito de Investigación de la Universidad de Sevillainstname:Universidad de Sevilla (US)InglésEnergy and Buildings, 250 (111302).https://www.sciencedirect.com/science/article/pii/S0378778821005867?via%3Dihubinfo:eu-repo/semantics/openAccessoai:idus.us.es:11441/1507092026-06-17T12:51:07Z |
| dc.title.none.fl_str_mv |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain |
| title |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain |
| spellingShingle |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain Caro Martínez, Rosa Ana Heritage housing Built heritage decarbonization Energy retrofit RES building integration Hybrid energy system Thermal comfort |
| title_short |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain |
| title_full |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain |
| title_fullStr |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain |
| title_full_unstemmed |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain |
| title_sort |
The role of hybrid systems in the decarbonization of residential heritage buildings in Mediterranean climate. A case study in Seville, Spain |
| dc.creator.none.fl_str_mv |
Caro Martínez, Rosa Ana Sendra, Juan J. Muñoz González, Carmen María |
| author |
Caro Martínez, Rosa Ana |
| author_facet |
Caro Martínez, Rosa Ana Sendra, Juan J. Muñoz González, Carmen María |
| author_role |
author |
| author2 |
Sendra, Juan J. Muñoz González, Carmen María |
| author2_role |
author author |
| dc.contributor.none.fl_str_mv |
Construcciones Arquitectónicas I TEP130: Arquitectura, Patrimonio y Sostenibilidad: Acústica, Iluminación, Óptica y Energía |
| dc.subject.none.fl_str_mv |
Heritage housing Built heritage decarbonization Energy retrofit RES building integration Hybrid energy system Thermal comfort |
| topic |
Heritage housing Built heritage decarbonization Energy retrofit RES building integration Hybrid energy system Thermal comfort |
| description |
Residential heritage buildings in the Mediterranean region face unexpected challenges in the field of energy efficiency and indoor environmental quality to ensure the sustainable conservation of historic town centres. This paper evaluates whether the conservation of their values can coexist with the current energy efficiency requirements and be included in urban decarbonization plans to prevent neglect and degradation. For this, a comprehensive decarbonization plan was drawn up based on the results of a previous energy audit on the case study selected, an 18th-century listed residential building in Seville, Spain. Envelope improvement was combined with mechanical ventilation and an integrated heat pump combining RESs and electricity from the public grid to cover all thermal needs in order to reach NZEB performance in the building. Despite the complexity of integrating demanding energy efficiency standards into heritage buildings, which requires case-by-case analysis and dynamic simulation, findings show a notable degree of approximation to NZEB performance. The main obstacles stem from the large amount of energy consumed by auxiliary systems and the relatively low presence of RESs in the national electricity mix. |
| publishDate |
2021 |
| dc.date.none.fl_str_mv |
2021 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion |
| format |
article |
| status_str |
acceptedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/11441/150709 https://doi.org/10.1016/j.enbuild.2021.111302 |
| url |
https://hdl.handle.net/11441/150709 https://doi.org/10.1016/j.enbuild.2021.111302 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Energy and Buildings, 250 (111302). https://www.sciencedirect.com/science/article/pii/S0378778821005867?via%3Dihub |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:idUS. Depósito de Investigación de la Universidad de Sevilla instname:Universidad de Sevilla (US) |
| instname_str |
Universidad de Sevilla (US) |
| reponame_str |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| collection |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869410288029138944 |
| score |
15.228081 |