ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography

Up to 40% of congenital diseases present disturbances of brain and craniofacial development resulting in simultaneous alterations of both systems. Currently, the best available method to preclinically visualize the brain and the bones simultaneously is to co-register micro-magnetic resonance (µMR) a...

ver descrição completa

Detalhes bibliográficos
Autores: Llambrich, Sergi, Wouters, Jens, Himmelreich, Uwe, Dierssen, Mara, Sharpe, James, Gsell, Willy, Martínez Abadías, Neus, Velde, Greetje Vande
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2020
País:España
Recursos:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:10230/46084
Acesso em linha:http://hdl.handle.net/10230/46084
http://dx.doi.org/10.1038/s41598-020-75720-3
Access Level:acceso abierto
Palavra-chave:Anatomia humana
Crani
Cara
Cervell
id ES_66da1e1d9fdf9b2592796aedc8ae6bbc
oai_identifier_str oai:recercat.cat:10230/46084
network_acronym_str ES
network_name_str España
repository_id_str
spelling ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomographyLlambrich, SergiWouters, JensHimmelreich, UweDierssen, MaraSharpe, JamesGsell, WillyMartínez Abadías, NeusVelde, Greetje VandeAnatomia humanaCraniCaraCervellUp to 40% of congenital diseases present disturbances of brain and craniofacial development resulting in simultaneous alterations of both systems. Currently, the best available method to preclinically visualize the brain and the bones simultaneously is to co-register micro-magnetic resonance (µMR) and micro-computed tomography (µCT) scans of the same specimen. However, this requires expertise and access to both imaging techniques, dedicated software and post-processing knowhow. To provide a more affordable, reliable and accessible alternative, recent research has focused on optimizing a contrast-enhanced µCT protocol using iodine as contrast agent that delivers brain and bone images from a single scan. However, the available methods still cannot provide the complete visualization of both the brain and whole craniofacial complex. In this study, we have established an optimized protocol to diffuse the contrast into the brain that allows visualizing the brain parenchyma and the complete craniofacial structure in a single ex vivo µCT scan (whiceCT). In addition, we have developed a new technique that allows visualizing the brain ventricles using a bilateral stereotactic injection of iodine-based contrast (viceCT). Finally, we have tested both techniques in a mouse model of Down syndrome, as it is a neurodevelopmental disorder with craniofacial, brain and ventricle defects. The combined use of viceCT and whiceCT provides a complete visualization of the brain and bones with intact craniofacial structure of an adult mouse ex vivo using a single imaging modality.The authors acknowledge research grants from CRG Awards ‘BrainFace’, the Jerome Lejeune Foundation (3M180477), KU Leuven BOF (C24/17/061, STG/15/024) and a 2-year doctoral fellowship from the Marie-Marguerite Delacroix Foundation to SLFNature Research202020202020info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttp://hdl.handle.net/10230/46084http://dx.doi.org/10.1038/s41598-020-75720-3reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésScientific Reports. 2020 Oct 30;10(1):18772© Sergi Llambrich et al. 2020. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were madehttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:recercat.cat:10230/460842026-05-29T05:05:01Z
dc.title.none.fl_str_mv ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography
title ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography
spellingShingle ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography
Llambrich, Sergi
Anatomia humana
Crani
Cara
Cervell
title_short ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography
title_full ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography
title_fullStr ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography
title_full_unstemmed ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography
title_sort ViceCT and whiceCT for simultaneous high-resolution visualization of craniofacial, brain and ventricular anatomy from micro-computed tomography
dc.creator.none.fl_str_mv Llambrich, Sergi
Wouters, Jens
Himmelreich, Uwe
Dierssen, Mara
Sharpe, James
Gsell, Willy
Martínez Abadías, Neus
Velde, Greetje Vande
author Llambrich, Sergi
author_facet Llambrich, Sergi
Wouters, Jens
Himmelreich, Uwe
Dierssen, Mara
Sharpe, James
Gsell, Willy
Martínez Abadías, Neus
Velde, Greetje Vande
author_role author
author2 Wouters, Jens
Himmelreich, Uwe
Dierssen, Mara
Sharpe, James
Gsell, Willy
Martínez Abadías, Neus
Velde, Greetje Vande
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Anatomia humana
Crani
Cara
Cervell
topic Anatomia humana
Crani
Cara
Cervell
description Up to 40% of congenital diseases present disturbances of brain and craniofacial development resulting in simultaneous alterations of both systems. Currently, the best available method to preclinically visualize the brain and the bones simultaneously is to co-register micro-magnetic resonance (µMR) and micro-computed tomography (µCT) scans of the same specimen. However, this requires expertise and access to both imaging techniques, dedicated software and post-processing knowhow. To provide a more affordable, reliable and accessible alternative, recent research has focused on optimizing a contrast-enhanced µCT protocol using iodine as contrast agent that delivers brain and bone images from a single scan. However, the available methods still cannot provide the complete visualization of both the brain and whole craniofacial complex. In this study, we have established an optimized protocol to diffuse the contrast into the brain that allows visualizing the brain parenchyma and the complete craniofacial structure in a single ex vivo µCT scan (whiceCT). In addition, we have developed a new technique that allows visualizing the brain ventricles using a bilateral stereotactic injection of iodine-based contrast (viceCT). Finally, we have tested both techniques in a mouse model of Down syndrome, as it is a neurodevelopmental disorder with craniofacial, brain and ventricle defects. The combined use of viceCT and whiceCT provides a complete visualization of the brain and bones with intact craniofacial structure of an adult mouse ex vivo using a single imaging modality.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020
2020
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/10230/46084
http://dx.doi.org/10.1038/s41598-020-75720-3
url http://hdl.handle.net/10230/46084
http://dx.doi.org/10.1038/s41598-020-75720-3
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Scientific Reports. 2020 Oct 30;10(1):18772
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Nature Research
publisher.none.fl_str_mv Nature Research
dc.source.none.fl_str_mv reponame:Recercat. Dipósit de la Recerca de Catalunya
instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
reponame_str Recercat. Dipósit de la Recerca de Catalunya
collection Recercat. Dipósit de la Recerca de Catalunya
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869409847165845504
score 15.812455