Comparison of long-term clinical outcomes in multivessel coronary artery disease patients treated either with bioresoarbable polymer sirolimus-eluting stent or permanent polymer everolimus-eluting stent: 5-year results of the CENTURY II randomized clinical trial
ObjectivesTo assess the long-term safety and efficacy of a sirolimus-eluting stent with bioresorbable polymer (BP-SES; Ultimaster), in comparison to a benchmark everolimus-eluting, permanent polymer stent (PP-EES; Xience), in a prespecified subgroup of patients with multivessel coronary artery disea...
| Autores: | , , , , , , , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2020 |
| País: | España |
| Institución: | Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau) |
| Repositorio: | r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau |
| OAI Identifier: | oai:iibsantpau.fundanetsuite.com:p2814 |
| Acceso en línea: | https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=2814 http://ddd.uab.cat/record/226436 |
| Access Level: | acceso abierto |
| Palabra clave: | clinical trials complex PCI coronary artery disease drug eluting percutaneous coronary intervention stent stent design structure coating |
| Sumario: | ObjectivesTo assess the long-term safety and efficacy of a sirolimus-eluting stent with bioresorbable polymer (BP-SES; Ultimaster), in comparison to a benchmark everolimus-eluting, permanent polymer stent (PP-EES; Xience), in a prespecified subgroup of patients with multivessel coronary artery disease (MVD) enrolled in the CENTURY II trial. BackgroundThe use of coronary stenting in high-risk subgroups, like MVD patients, is rising. The clinical evidence, including long-term comparative analysis of the efficacy and safety benefits of different new-generation drug eluting stents, however, remains insufficient. MethodsAmong 1,119 patients (intention-to-treat) enrolled in the CENTURY II prospective, randomized, single-blind, multicenter trial, a prespecified subgroup of 456 MVD patients were allocated by stratified randomization to treatment with BP-SES (n =225) or PP-EES (n =231). The previously reported primary endpoint of this study was freedom from target lesion failure (TLF: a composite of cardiac death, target vessel-related myocardial infarction [MI] and clinically-indicated target lesion revascularization) at 9months. ResultsIn this MVD substudy, baseline patient, lesion and procedure characteristics were similar between the treatment arms. At 1 and 5 years, both BP-SES and PP-EES displayed low and comparable rates of TLF (5.3 vs. 7.8%; p =.29 and 10.2 vs. 13.4%; p =.29), and definite or probable stent thrombosis (0.4 vs. 1.3%; p =.33 and 0.9 vs. 1.7%; p =.43), respectively. Composite endpoint of cardiac death and MI, and patient-oriented composite endpoint of any death, MI, and coronary revascularizations were also similar. ConclusionsThese results confirm good long-term safety and efficacy of the studied bioresorbable polymer stent in this high-risk patient population. |
|---|