Evaluation of an Ozone Chamber as a Routine Method to Decontaminate Firefighters' PPE

Ozone chambers have emerged as an alternative method to decontaminate firefighters' Personal Protective Equipment (PPE) from toxic fire residues. This work evaluated the efficiency of using an ozone chamber to clean firefighters' PPE. This was achieved by studying the degradation of pyrene...

ver descrição completa

Detalhes bibliográficos
Autores: Melo Lucena, Marcella A. de, Zapata Arráez, Félix|||0000-0002-7419-4632, Mauricio Martínez, Filipe Gabriel, Ortega Ojeda, Fernando Ernesto, Quintanilla López, María Gloria, Távora Weber, Ingrid, Montalvo García, Gemma|||0000-0002-5640-8908
Formato: artículo
Fecha de publicación:2021
País:España
Recursos:Universidad de Alcalá (UAH)
Repositorio:e_Buah Biblioteca Digital Universidad de Alcalá
Idioma:inglés
OAI Identifier:oai:ebuah.uah.es:10017/60830
Acesso em linha:http://hdl.handle.net/10017/60830
https://dx.doi.org/10.3390/ijerph182010587
Access Level:acceso abierto
Palavra-chave:ozone
ozonolysis
firefighters
work safety
personal protective clothes (PPC)
decontamination
polycyclic aromatic hydrocarbons (PAH)
Química
Chemistry
Descrição
Resumo:Ozone chambers have emerged as an alternative method to decontaminate firefighters' Personal Protective Equipment (PPE) from toxic fire residues. This work evaluated the efficiency of using an ozone chamber to clean firefighters' PPE. This was achieved by studying the degradation of pyrene and 9-methylanthracene polycyclic aromatic hydrocarbons (PAHs). The following experiments were performed: (i) insufflating ozone into PAH solutions (homogeneous setup), and (ii) exposing pieces of PPE impregnated with the PAHs to an ozone atmosphere for up to one hour (heterogeneous setup). The ozonolysis products were assessed by Fourier Transform Infrared Spectroscopy (FTIR), Thin-Layer Chromatography (TLC), and Mass Spectrometry (MS) analysis. In the homogeneous experiments, compounds of a higher molecular weight were produced due to the incorporation of oxygen into the PAH structures. Some of these new compounds included 4-oxapyren-5-one (m/z 220) and phenanthrene-4,5-dicarboxaldehyde (m/z 234) from pyrene; or 9-anthracenecarboxaldehyde (m/z 207) and hydroxy-9,10-anthracenedione (m/z 225) from 9-methylanthracene. In the heterogeneous experiments, a lower oxidation was revealed, since no byproducts were detected using FTIR and TLC, but only using MS. However, in both experiments, significant amounts of the original PAHs were still present even after one hour of ozone treatment. Thus, although some partial chemical degradation was observed, the remaining PAH and the new oxygenated-PAH compounds (equally or more toxic than the initial molecules) alerted us of the risks to firefighters' health when using an ozone chamber as a unique decontamination method. These results do not prove the ozone-advertised efficiency of the ozone chambers for decontaminating (degrading the toxic combustion residues into innocuous compounds) firefighters' PPE.