Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.

The objective of this preliminary study was to determine the reproducibility of lower limbs skin temperature after cold stress test using the Game Ready system. Skin temperature of fourteen participants was measured before and after cold stress test using the Game Ready system and it was repeated th...

Full description

Bibliographic Details
Authors: Priego-Quesada, Jose Ignacio, Gandia-Soriano, Alexis, Pellicer-Chenoll, Maria Teresa, Catala-Vilaplana, Ignacio, Bermejo-Ruiz, Jose Luis, Encarnacion-Martinez, Alberto, Salvador-Palmer, Rosario, Cibrian Ortiz de Anda, Rosa
Format: article
Status:Published version
Publication Date:2021
Country:España
Institution:INCLIVA
Repository:r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
OAI Identifier:oai:incliva.fundanetsuite.com:p15916
Online Access:https://incliva.portalinvestigacion.com/publicaciones/15916
Access Level:Open access
Keyword:cooling
cryotherapy
dynamic thermography
infrared thermography
medicine
posterior leg
id ES_3db1be9aa7f398a1d86cf9fef6df34a4
oai_identifier_str oai:incliva.fundanetsuite.com:p15916
network_acronym_str ES
network_name_str España
repository_id_str
spelling Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.Priego-Quesada, Jose IgnacioGandia-Soriano, AlexisPellicer-Chenoll, Maria TeresaCatala-Vilaplana, IgnacioBermejo-Ruiz, Jose LuisEncarnacion-Martinez, AlbertoSalvador-Palmer, RosarioCibrian Ortiz de Anda, Rosacoolingcryotherapydynamic thermographyinfrared thermographymedicineposterior legThe objective of this preliminary study was to determine the reproducibility of lower limbs skin temperature after cold stress test using the Game Ready system. Skin temperature of fourteen participants was measured before and after cold stress test using the Game Ready system and it was repeated the protocol in four times: at 9:00, at 11:00, at 19:00, and at 9:00 h of the posterior day. To assess skin temperature recovery after cold stress test, a logarithmic equation for each region was calculated, and constant (ß(0)) and slope (ß(1)) coefficients were obtained. Intraclass correlation coefficient (ICC), standard error (SE), and within-subject coefficient of variation (CV) were determined. No differences were observed between measurement times in any of the regions for the logarithmic coefficients (p > 0.38). Anterior thigh (ß(0) ICC 0.33-0.47; ß(1) ICC 0.31-0.43) and posterior knee (ß(0) ICC 0.42-0.58; ß(1) ICC 0.28-0.57) were the regions with the lower ICCs, and the other regions presented values with a fair and good reproducibility (ICC > 0.41). Posterior leg was the region with the better reproducibility (ß(0) ICC 0.68-0.78; ß(1) ICC 0.59-0.74; SE 3-4%; within-subject CV 7-12%). In conclusion, cold stress test using Game Ready system showed a fair and good reproducibility, especially when the posterior leg was the region assessed.MDPI2021info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://incliva.portalinvestigacion.com/publicaciones/15916International Journal of Environmental Research and Public HealthISSN: 16617827ISSNe: 16604601reponame:r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVAinstname:INCLIVAInglésinfo:eu-repo/semantics/openAccessoai:incliva.fundanetsuite.com:p159162026-06-07T16:35:31Z
dc.title.none.fl_str_mv Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.
title Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.
spellingShingle Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.
Priego-Quesada, Jose Ignacio
cooling
cryotherapy
dynamic thermography
infrared thermography
medicine
posterior leg
title_short Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.
title_full Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.
title_fullStr Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.
title_full_unstemmed Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.
title_sort Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study.
dc.creator.none.fl_str_mv Priego-Quesada, Jose Ignacio
Gandia-Soriano, Alexis
Pellicer-Chenoll, Maria Teresa
Catala-Vilaplana, Ignacio
Bermejo-Ruiz, Jose Luis
Encarnacion-Martinez, Alberto
Salvador-Palmer, Rosario
Cibrian Ortiz de Anda, Rosa
author Priego-Quesada, Jose Ignacio
author_facet Priego-Quesada, Jose Ignacio
Gandia-Soriano, Alexis
Pellicer-Chenoll, Maria Teresa
Catala-Vilaplana, Ignacio
Bermejo-Ruiz, Jose Luis
Encarnacion-Martinez, Alberto
Salvador-Palmer, Rosario
Cibrian Ortiz de Anda, Rosa
author_role author
author2 Gandia-Soriano, Alexis
Pellicer-Chenoll, Maria Teresa
Catala-Vilaplana, Ignacio
Bermejo-Ruiz, Jose Luis
Encarnacion-Martinez, Alberto
Salvador-Palmer, Rosario
Cibrian Ortiz de Anda, Rosa
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv cooling
cryotherapy
dynamic thermography
infrared thermography
medicine
posterior leg
topic cooling
cryotherapy
dynamic thermography
infrared thermography
medicine
posterior leg
description The objective of this preliminary study was to determine the reproducibility of lower limbs skin temperature after cold stress test using the Game Ready system. Skin temperature of fourteen participants was measured before and after cold stress test using the Game Ready system and it was repeated the protocol in four times: at 9:00, at 11:00, at 19:00, and at 9:00 h of the posterior day. To assess skin temperature recovery after cold stress test, a logarithmic equation for each region was calculated, and constant (ß(0)) and slope (ß(1)) coefficients were obtained. Intraclass correlation coefficient (ICC), standard error (SE), and within-subject coefficient of variation (CV) were determined. No differences were observed between measurement times in any of the regions for the logarithmic coefficients (p > 0.38). Anterior thigh (ß(0) ICC 0.33-0.47; ß(1) ICC 0.31-0.43) and posterior knee (ß(0) ICC 0.42-0.58; ß(1) ICC 0.28-0.57) were the regions with the lower ICCs, and the other regions presented values with a fair and good reproducibility (ICC > 0.41). Posterior leg was the region with the better reproducibility (ß(0) ICC 0.68-0.78; ß(1) ICC 0.59-0.74; SE 3-4%; within-subject CV 7-12%). In conclusion, cold stress test using Game Ready system showed a fair and good reproducibility, especially when the posterior leg was the region assessed.
publishDate 2021
dc.date.none.fl_str_mv 2021
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://incliva.portalinvestigacion.com/publicaciones/15916
url https://incliva.portalinvestigacion.com/publicaciones/15916
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv International Journal of Environmental Research and Public Health
ISSN: 16617827
ISSNe: 16604601
reponame:r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
instname:INCLIVA
instname_str INCLIVA
reponame_str r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
collection r-INCLIVA. Repositorio Institucional de Producción Científica de INCLIVA
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869406463564185600
score 15,812455