Influence of inter-electrode distance, contraction type, and muscle on the relationship between the sEMG power spectrum and contraction force

Introduction Spectral frequencies of the surface electromyogram (sEMG) increase with contraction force, but debate still exists on whether this increase is affected by various methodological and anatomical factors. This study aimed to investigate the influence of inter-electrode distance (IED) and c...

Full description

Bibliographic Details
Authors: Rodríguez Falces, Javier, Neyroud, Daria, Place, Nicolas
Format: article
Status:Versión aceptada para publicación
Publication Date:2014
Country:España
Institution:Universidad Pública de Navarra
Repository:Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
OAI Identifier:oai:academica-e.unavarra.es:2454/55584
Online Access:https://hdl.handle.net/2454/55584
Access Level:Open access
Keyword:Power spectral analysis
Median frequency
Ramp contractions
Step-wise contractions
Inter-electrode distance
Fibre-type distribution
Description
Summary:Introduction Spectral frequencies of the surface electromyogram (sEMG) increase with contraction force, but debate still exists on whether this increase is affected by various methodological and anatomical factors. This study aimed to investigate the influence of inter-electrode distance (IED) and contraction modality (step-wise vs. ramp) on the changes in spectral frequencies with increasing contraction strength for the vastus lateralis (VL) and vastus medialis (VM) muscles. Methods Twenty healthy male volunteers were assessed for isometric sEMG activity of the VM and VL, with the knee at 90° flexion. Subjects performed isometric ramp contractions in knee extension (6-s duration) with the force gradually increasing from 0 to 80 % MVC. Also, subjects performed 4-s step-wise isometric contractions at 10, 20, 30, 40, 50, 60, 70, and 80 % MVC. Interference sEMG signals were recorded simultaneously at different IEDs: 10, 20, 30, and 50 mm. The mean (Fmean) and median (Fmedian) frequencies and root mean square (RMS) of sEMG signals were calculated. Results For all IEDs, contraction modalities, and muscles tested, spectral frequencies increased significantly with increasing level of force up to 50–60 % MVC force. Spectral indexes increased systematically as IED was decreased. The sensitivity of spectral frequencies to changes in contraction force was independent of IED. The behaviour of spectral indexes with increasing contraction force was similar for step-wise and ramp contractions. Conclusions In the VL and VM muscles, it is highly unlikely that a particular inter-electrode distance or contraction modality could have prevented the observation of the full extent of the increase in spectral frequencies with increasing force level.