Aumento da eficiência de painéis fotovoltaicos com esfriamento por energia geotérmica e aquecimento de água

This thesis deals with the increased efficiency of photovoltaic panels (PVs) through cooling the cells by geothermal energy and water heating. Initially, a photovoltaic modeling is made proposing an equation to obtain the maximum power point considering the variations of solar radiation and cell tem...

Full description

Bibliographic Details
Author: Fernandes, Felipe Teixeira
Format: master thesis
Status:Published version
Publication Date:2014
Country:Brasil
Institution:Universidade Federal de Santa Maria (UFSM)
Repository:Manancial - Repositório Digital da UFSM
Language:Portuguese
OAI Identifier:oai:repositorio.ufsm.br:1/8541
Online Access:http://repositorio.ufsm.br/handle/1/8541
Access Level:Open access
Keyword:Painéis fotovoltaicos
Modelagem matemática
Energia geotérmica
Ponto de máxima potência
Esfriamento e eficiência energética
Photovoltaic panels
Mathematical modeling
Geothermal energy
Maximum power point and energy efficiency
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Description
Summary:This thesis deals with the increased efficiency of photovoltaic panels (PVs) through cooling the cells by geothermal energy and water heating. Initially, a photovoltaic modeling is made proposing an equation to obtain the maximum power point considering the variations of solar radiation and cell temperature. Initially, it is proposed a PV modeling for obtaining the maximum power point (MPP) as a function of solar radiation and temperature of the cells by the PV 5-parameter model. Thus, the determination of the PV MPP, which depends only on the internal parameters, can be made with greater precision. Water circulation by a pipe that passes through the thermal reservoir is used to cool the PV. This is complemented by cooling hoses buried underground to exchange geothermal avoiding the saturation of the heat exchange between PV and water circulation, increasing the PV efficiency. After studies on the constitution of the soil, the technical characteristics of the tubes for circulating water, hydraulic pump and heat exchanger installed after PV, economic analysis and a set of two PVs were mounted with and without the heat exchangers to verify the gains in power and performance. The experiments were made with two PVs operating in MPP, proving that the MPP and the performance increase with decreasing temperature as the modeling performed. During the experiments, the underground temperature varied slightly, avoiding the heat exchange saturation. The main contributions include the PV modeling to obtain the MPP with a single iteration, the use of geothermal energy without heat pump and residential heat load reduction by use of heated water circulation in PVs.