Estudo do segmento anterior com a câmera rotatória de Scheimpflug em pacientes candidatos à cirurgia refrativa
PURPOSE: To analyze the anterior segment of refractive surgery candidates and establish the variability pattern in this population regarding corneal volume, anterior chamber volume and depth and corneal thickness, using the noncontact three dimensional analyzer Pentacam®. METHODS: A retrospective st...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2007 |
| País: | Brasil |
| Institución: | Universidade Federal de São Paulo (UNIFESP) |
| Repositorio: | Repositório Institucional da UNIFESP |
| Idioma: | portugués |
| OAI Identifier: | oai:repositorio.unifesp.br:11600/3846 |
| Acceso en línea: | http://dx.doi.org/10.1590/S0004-27492007000400012 http://repositorio.unifesp.br/handle/11600/3846 |
| Access Level: | acceso abierto |
| Palabra clave: | Corneal topography Myopia Hyperopia Anterior eye segment Topografia da córnea Miopia Hiperopia Segmento anterior do olho |
| Sumario: | PURPOSE: To analyze the anterior segment of refractive surgery candidates and establish the variability pattern in this population regarding corneal volume, anterior chamber volume and depth and corneal thickness, using the noncontact three dimensional analyzer Pentacam®. METHODS: A retrospective study of 297 eyes of 149 patients was conducted using Pentacam®. According to the spherical equivalent value two groups were created, myopia (n=242 eyes) and hyperopia (n=55 eyes), to analyze the variables of corneal volume, anterior chamber volume and depth and corneal thickness. RESULTS: The mean values of the myopia group were: corneal total volume 59.37 ± 3.51mm³, corneal volume at 3 mm 3.87 ± 0.23 mm³, at 5 mm 11.31 ± 0.67 mm³, and at 7 mm 24.30 ± 1.43 mm³, anterior chamber volume 198.74 ± 32.40 mm³, anterior chamber depth 3.19 ± 0.28 mm and corneal thickness 533.33 ± 33.47 mm. In the hyperopia group, the mean total corneal volume was 60.77 ± 3.31 mm³, corneal volume at 3 mm from the apex was 4.01 ± 0.20 mm³, at 5 mm was 11.73 ± 0.58 mm³, and at 7 mm was 25.09 ± 1.21 mm³, the anterior chamber volume was 146.61 ± 32.86 mm³, the anterior chamber depth was 2.76 ± 0.38 mm and the corneal thickness was 550.52 ± 29.49 mm. The difference between the groups was significant for all variables (p<0.05). CONCLUSION: We observed in this study that patients with myopia had lesser mean corneal volume and pachymetry, and greater anterior chamber depth and volume compared with hyperopic patients. |
|---|