Intraocular pressure after myopic laser refractive surgery measured with a new Goldmann convex prism

The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and Ocular Respo...

ver descrição completa

Detalhes bibliográficos
Autores: Iglesias, María|||0000-0002-4482-0276, Kudsieh, Bachar|||0000-0002-2600-8233, Laiseca, Andrea, Santos, Cristina|||0000-0002-7014-8014, Nadal Reus, Jeroni, Barraquer, Rafael I. (Rafael Ignasi)|||0000-0002-8062-2998, Casaroli-Marano, Ricardo Pedro|||0000-0003-1812-9323
Tipo de documento: artigo
Data de publicação:2022
País:España
Recursos:Universitat Autònoma de Barcelona
Repositório:Dipòsit Digital de Documents de la UAB
Idioma:inglês
OAI Identifier:oai:ddd.uab.cat:256063
Acesso em linha:https://ddd.uab.cat/record/256063
https://dx.doi.org/urn:doi:10.1186/s12886-022-02309-x
Access Level:Acceso aberto
Palavra-chave:Tonometry
Corneal biomechanics
Intraocular pressure
Glaucoma
Myopia
LASIK
PRK
Descrição
Resumo:The purpose of this study is to describe measurements using a newly developed modified Goldmann convex tonometer (CT) 1 year after myopic laser refractive surgery. Intraocular pressure (IOP) measurements were compared with IOP values obtained by Goldmann applanation tonometer (GAT), and Ocular Response Analyzer (ORA). Prospective double-masked study performed on thirty eyes of thirty patients that underwent laser in situ keratomileusis (LASIK; n = 19) or photorefractive keratectomy (PRK; n = 11). IOP was measured before and 3 and 12 months after surgery. Intraclass correlation coefficient (ICC) and Bland-Altman plot were calculated to assess the agreement between GAT, CT, IOPg (Goldmann-correlated IOP) and IOPcc (corneal-compensated IOP) from ORA. Twelve months after LASIK, IOP measured with CT showed the best correlation with IOP measured with GAT before surgery (GATpre) (ICC = 0.886, 95% CI: 0.703-0.956) (15.60 ± 3.27 vs 15.80 ± 3.22; p < 0.000). However, a moderate correlation was found for IOP measured with IOPcc and CT 12 months after LASIK (ICC = 0.568, 95% CI: - 0.185 - 0.843) (15.80 ± 3.22 vs 12.87 ± 2.77; p < 0.004). Twelve months after PRK, CT showed a weak correlation (ICC = - 0.266, 95% CI: - 3.896 - 0.663), compared to GATpre (17.30 ± 3.47 vs 16.01 ± 1.45; p < 0.642), as well as poor correlation (ICC = 0.256, 95% CI: - 0.332 - 0.719) with IOPcc (17.30 ± 3.47 vs 13.38 ± 1.65; p < 0.182). Twelve months after LASIK, IOP measured with CT strongly correlated with GAT before surgery and could therefore provide an alternative method for measuring IOP after this surgery. More studies regarding this new convex prism are needed to assess its accuracy.